Architecture and 28A blackout simulation, in two scrolls.

How DCF-GRID ingests PMU/SCADA data and produces a predictive horizon. The signals shown are reproduced from the public REE / ENTSO-E / MedFasee technical reports of the 28 April 2025 Iberian blackout — the 0.6 Hz inter-area oscillation, the post-intervention damped phase, the silent drift, the cascade.

01 / Architecture

Inputs · sealed engine · outputs the operator can act on.

DCF-GRID integrates as a non-intrusive software layer over existing PMU and SCADA environments. The proprietary engine is sealed by design — auditable on request under NDA, never exposed publicly. The signals it consumes and the signals it returns are open and standard.

INPUTS · OPERATIONAL DATA DCF ENGINE · PROPRIETARY OUTPUTS · TO OPERATOR PMU · synchrophasor data SCADA · system state Frequency · voltage ROCOF · phase angle Active & reactive power Inertia estimate · H DCF ENGINE Proprietary · Sealed by design Auditable under NDA PI · MA-176-26 TRADE SECRET · LEY 1/2019 Hp(t) · Predictive horizon useful manoeuvre time Zone classification safe / critical / imminent Operator alert accionable · time-stamped Recommended action FRR · curtailment · etc. INTEGRATION LAYER IEC 61850 · ICCP · REST API · Oracle Cloud EU · GDPR-native · CER & NIS2 alignment
02 / Live simulation

The 28A as it happened, with the horizon overlay.

PMU/SCADA signals reproduced from the published 28A timeline: 0.6 Hz inter-area oscillation between 12:02 and 12:08, post-intervention damping, silent drift, voltage rise in the southwest, cascade onset at 12:30, frequency collapse at 12:33. The Hp predictive horizon is computed continuously from the same input signals via an illustrative stress-to-time model — actual DCF computation is proprietary under NDA.

28 April 2025 · public REE / ENTSO-E / MedFasee timeline PMU/SCADA ingestion vs. predictive horizon
CEST · 12:00 → 12:33 12:02
12:0012:0812:1512:2212:3012:33
PMU / SCADA · transient evaluation · predictive horizon STREAMING
FREQUENCY Hz · 47.0 → 50.5 50.0 47.0 6 min ROCOF Hz/s 0 VOLTAGE pu 1.00 Hp · PREDICTIVE HORIZON minutes · illustrative SAFE ATTN CRIT IMMI COLL 30m 25m 15m 5m 0 14:45 Hp 12:00 12:08 12:15 12:22 12:30 12:02 osc onset 12:08 damped 12:30 gen loss 12:33 cascade
Frequency
50.00 Hz
ROCOF
+0.00 Hz/s
Voltage
1.000 pu
Hp · DCF
29:30 min
DCF-GRID · predictive horizon SAFE
Estimated useful manoeuvre time · Hp
29:30
System within nominal envelope
SafeAttentionCriticalImminentCollapse
MONITOR System operating within nominal envelope. Continue monitoring.

Public timeline · REE / ENTSO-E / MedFasee

! Illustrative reconstruction. Frequency, ROCOF and voltage signals are physical reproductions of the public 28A timeline. The Hp predictive horizon is computed continuously from those signals using a generic stress-to-time proxy — not the proprietary DCF algorithm, which is shared exclusively under signed NDA. DCF-GRID would not have prevented the blackout; it would have provided the predictive horizon that current systems did not produce.